Glo Controls Gas Appliance Controls provide enhanced functionality and the highest level of safety and performance
The DSI Oven Control (DSOC01-2C) is a compact electronic device used in gas appliances. It provides two gas valve outputs and two independent direct spark outputs, controlled by rectification flame sense circuits using common ignition and sense electrodes.
The DSIOC01-2C is a two channel oven control, providing all the required functions for safe control of two 120 (or 230) Vac gas valves, ignition, and flame sensing.
The Hot Surface Ignition Oven Control (HSOC02-2C) is a compact electronic device used in gas appliances. It provides two gas valve outputs and two independent hot surface ignition outputs, controlled by rectification flame sense circuits using common ignition and sense electrodes.
By using flame sense technology our Hot Surface Oven Control is only activated during the ignition sequence thereby extending the life of the element and reducing power usage.
In contrast to broadly used flame sense technology, the HSI and DSI are tolerant of line and neutral connection swap.
The HSOC02-2C is a two channel oven control, providing all the required functions for safe control of two 120 (or 230) Vac gas valves, ignition, and flame sensing.
In addition, both the DSI and HSI provides safety monitory and will not light the gas without proper safety protocols being met.
Both the DSI and HSI can be used in other gas safety applications to safely ignite your gas appliance.
HSI Features
- 120 or 230V operation, 50 or 60Hz operation (different models)
- Standby power < 2W
- Two independent channels
- Detection of system faults Tolerant of line and neutral connection swap
- Programmable safety and purge times, ignition and re-ignition attempts
- Status display LED (can be remotely mounted)
- Serial port for production line testing or programming
- Compliant to CE and CSA 60730-2-5 safety standards
- The HSE oven controller may be programmed with alternative parameters or additional features according customer requirements
- Performs all necessary safety checks before energising gas valves.
- Status LED indicates fault if any abnormal condition is detected.
- This Controller is also suitable for use with isolation transformers
DSI Features
- 120 or 230V operation, 50 or 60Hz operation (different models)
- Standby power approx 0.5W
- Two independent channels
- Detection of system faults Tolerant of line and neutral connection swap
- Programmable safety and purge times, ignition and re-ignition attempts
- Status display LED (can be remotely mounted)
- Serial port for production line testing or programming
- Compliant to CE and CSA 60730-2-5 safety standards
- The DSI oven controller may be programmed with alternative parameters or additional features according customer requirements
- Performs all necessary safety checks before energising gas valves. Status LED indicates fault if any abnormal condition is detected.
- This Controller is also suitable for use with isolation transformers
Download Brochures
HSI Specifications
Parameter |
Units |
|
Line Voltage (110V version) |
110 |
V |
Frequency (60Hz version) |
60 |
Hz |
Gas Valve Nominal Voltage (110V version) |
24 |
V |
Output Typical Power (at Hot HSE) |
50 |
W |
Electronic Control Suitable to be used with a generic 24V / 50W igniter (110V version) | ||
Flame Sense Current |
0.5 |
uA |
Operating Temperature (continuous) |
105 |
oC |
Relative Humidity (at 40oC – non condensing) |
95 |
% |
Ignition Attempts |
6 (programmable) |
|
Re-Ignition Attempts |
4 (programmable) |
|
Purge Period (programmable) |
30 |
Sec |
DSI Specifications
Parameter |
Units |
|
Line Voltage (110V version) |
110 |
V |
Frequency (60Hz version) |
60 |
Hz |
External solenoid rated Voltage |
120 |
Vac |
External Solenoid Power |
15 |
W |
Electronic Control Suitable to be used with a generic 24V / 50W igniter (110V version) | ||
Flame Sense Current |
0.5 |
uA |
Operating Temperature (continuous) |
105 |
oC |
Relative Humidity (at 40oC – non condensing) |
95 |
% |
Ignition Attempts |
6 (programmable) |
|
Re-Ignition Attempts |
4 (programmable) |
|
Purge Period (programmable) |
30 |
Sec |